kubota l3400 won't start
follow that with all the safety switches in the path to engaging the start relay. Any thoughts? Mine has a switch for each of the two gear shift levers. If you would like to change your settings or withdraw consent at any time, the link to do so is in our privacy policy accessible from our home page.. Disconnect the line which connects the fuel filter and the fuel pump. Check the Deadman switch under the seat? JavaScript is disabled. JavaScript is disabled. Battery cables Defective or dirty battery cables are the problem more often than you might think. Changing fuel filter introduces air in the injectors and wont start until bled out. 352K views 6 years ago if your Kubota tractor won't start watch this video - and try this first. If the tractor starts off good, works for some time, and suddenly stops while in use, the most common reason is fuel starvation. If the diesel fuel pours as it leaves the line, there may be something clogged in the line. Nonetheless, I'm the man of the farm, so this repair falls on me. So run the battery voltage test again. Check for voltage there and if not figure out why. Try what RockyRidge said, rock the HST pedal "sloooowly" with the key in the start positionmy L2800 used to do this fairly regularly and no it will not fail for the dealer if it is like mine it will get better, I haven't had to rock my pedal in many months. People need to turn off the vehicle to operate it again. The safety switch on the foot pedal has been a problem. After that, check the voltage of the battery. if it is good, in other words it doesnt drop below about 11 volts. If your Kubota diesel engine does not start, begin by confirming that your electrical and fuel delivery systems are performing properly. Thats usually me. what I found was that not enough. Some of our partners may process your data as a part of their legitimate business interest without asking for consent. Can it be solved at home? if it is very low there, then by all means clean/repair the connections. If this is HST, rock your forward/reverse pedal back and forth while holding the key in the crank position. Do they at least give you a reach around? Press question mark to learn the rest of the keyboard shortcuts. If the tractor starts off good, works for some time, and suddenly stops while in use, the most common reason is fuel starvation. You must log in or register to reply here. Mostly this creates the problem. Welcome. Kansas, Butler county, Just east of DooDah. We and our partners use cookies to Store and/or access information on a device. We have 5 Kubota L3400 manuals available for free PDF download: Workshop Manual, Operator's Manual . If you have 12V then have someone turn the key on while you listen to see if it starts. Does the display say anything about OPC? I'm smart and relatively mechanically inclined, but I don't have a lot of experience with diesel or tractors, much less diesel tractors. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. You are using an out of date browser. It appears to be in Neutral, but is not and will not start after I turned the switch off. Buts that's where the real. I have problem but it is not the seat switch because the PTO continues to rotate whether I am on the seat or not. For a better experience, please enable JavaScript in your browser before proceeding. Best Evergreen Trees to Plant In New York, 10 Evergreen Trees to Plant in North Carolina, 5 Common Problems with John Deere 4120 (Solutions Included), Most Common Problems with John Deere 5045E (Solutions Added), 6 Most Common Problems with Massey Ferguson 240, 5 Most Common Problems with Bobcat T770 (Solutions Included), Most Common Problems with John Deere 750 (Solutions Added). Today went to start the tractor and it won't start. Got up the next day, no start. Evacuator Valve. To know in detail, read on. Welcome. if it is good, in other words it doesnt drop below about 11 volts. Put the solenoid back on and it would start but then die immediately. For a better experience, please enable JavaScript in your browser before proceeding. You need to get a tester light and follow the current. I got this tractor from my grand father that passed last year, about 2800 hours on it, my fathers friend helped tow it over and has been sitting beside the RV under our car part since, it has been ran a few times with no issues. I hope this article has given you a solid idea of where to start. . Join us in searching for a Kubota diesel that will not start in the cold weather. It may not display this or other websites correctly. Today it won't start. i even bushogged with it for 3 hours. My relatively new (71 hours) Kubota L3400 will not start. You have found you high resistance problem. Can someone pinpoint where the fuel solenoid is located on the L3400HST? So, you need to check the battery first if you are facing this kind of problem. You have found you high resistance problem. Mechanical: Chassis: 4x2 2WD : 4x4 MFWD 4WD: Differential lock: rear standard: Steering: Charged the battery, check the continuity on the fuses, traced power to the starter Ask an Expert Car Questions Agriculture and Farm Equipment Is the concern it will not crank or it will not start? Sometimes it well run for a few seconds other times a few minutes. Maybe try jumping the starter just to see if it turns over. Is the large wire on the starter near 12.6 volts? Overall, it increases the productivity of the tractor. The more I read about fuel solenoid the more I think my tractor non-run problem may be related to the fuel solenoid. / Simple Trouble Shooting RudydaGoat 163 subscribers Subscribe Share 54K views 3 years ago Just on that one mission i learned lots. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. You are using an out of date browser. There are several ways to solve this problem. The fuel solenoid is not clicking when the key is turned. Make sure there is good voltage at the lift pump. Established in 2009, we are the largest online community of Kubota tractor and equipment owners. Or bad battery connection(s). Most times I get no click from the solenoid. Any help would be appreciated. Some times the solenoid engages other times not. Charged the battery, Charged the battery, check the continuity on the fuses, traced power to the starter read more Chris (aka-Moose) Technician 363 satisfied customers 2015 Kubota 3350 w/cab . Many thanks. Aug 9, 2021. Please post back. At the end of the fuel rail is a valve. If not, try to see a professional who can fix the problem for you. Replace the oil with some light oil. Changing Engine Oil. First, never use starting fluid in a diesel. 250 an hour?!? Why is the steering wheel spinning very easily? Or maybe one of the PTOs are engaged? 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. Last week i got it out to pull a small tree and did great, put it back under the car port, came back the next day, started right up, drove about 50feet and quit, the engine turns over fine, but won't fire. Kubota has no idea what it is, and i'm not going to the place that gave me that quote, we jumped it for now. For a better experience, please enable JavaScript in your browser before proceeding. You will find the downside of the cable. JavaScript is disabled. If it's got 12v at battery but no instrument panel lights, I'd suspect the switch. BUT when you said a humming sound, I bet its the battery dropping under load and you are hearing a relay trying to pull in. Turn the dial to the lowest setting in the resistance mode in the ohms portion of the meter. For almost a Month I could not start the Kubota Tractor, come to find out after testing. For a better experience, please enable JavaScript in your browser before proceeding. You need to get a service book for this tractor with a wiring diagram. then put the leads on the clamp connections and read it there. Check if it is dead or have any other problem. Anything and everything about Kubota. Closed the air vent cock. It generally happens if there are any battery issues. Then start with the battery. or the starter engage, you need to know if it is the battery, or high resistance/ connection or something. For a better experience, please enable JavaScript in your browser before proceeding. Today went to start the tractor and it won't start. Don't really have that for something that doesn't get used much. Injection pumps rarely fail. It happens when the spring load is seized up and does not slide properly. LOL. It should solve the problem. If there is any water mixed with the oil then the engine can stall. Kubota enthusiasts, hobbyists, and fans! Read somewhere that the fuel solenoid can cause the issue. if its filled with dirt and thick mud-like object, you need to replace the filter. The consent submitted will only be used for data processing originating from this website. Not starting, shutting off after some time, POT not turning on, and RPM slowing down are the common kubota l3400 problems. I got this tractor from my grand father that passed last year, about 2800 hours on it, my fathers friend helped tow it over and has been sitting beside the RV under our car part since, it has been ran a few times with no issues. Dead battery? Definitely sounds like a fuel pump issue. Most failures to start with what you have described is from a faulty safety switch or just being out of adjustment. Sounds like an obstruction or bad lift pump. I am a little suspicious of the deadman switch, because lately when I've gotten off the tractor to move something or whatever, the engine will stop. I have a Kubota L3400 with Manual transmission, 4WD. Fix all the connections battery has with other parts of the vehicle. The dash lights come on, but when I turn the key all the way there is no click or response at all from the starter. 900 to tow it?!? The air cleaner can be clogged or an unadjusted engine valve can cause this problem. Did you run it out of fuel? If not then your solenoid could be bad if so then you have bigger issues that need deeper troubleshooting. Then check the wiring. You need a multimeter to start checking voltages. Battery is good. After that, it will pick it up in about a minute or so. Another common problem in Kubota is not getting started at all but just clicking. The first time it happened, it was 10 minutes before I figured it out. My Kubota l3400 tractor won't start. then put the leads on the clamp connections and read it there. Or if there is any faulty safety switch, it needs to replace too. If not the you have your culprit. What happens here is, that every other gear works fine and when you try to use that particular gear. That isn't an issue. It's diesel so it's probably either the injection pump or the lift pump. Thanks for this threadI was packing up today and this happenednever thought to mess with the pedal until I read this and it started up after a couple of pushes. One was a simple matter of lubing the bottom end of the cable assembly that operates the PTO. We and our partners use data for Personalised ads and content, ad and content measurement, audience insights and product development. The issue is most likely another safety switch. tank is 3/4 full, new fuel filter, my fathers friend came over and sprayed diesel in the intake and it started running a bit but soon as he stopped, engine stopped. With the key in, turning it to the left does nothing (no lights on dash, etc), Turning the key to start does absolutely nothing, Turning the key to the spot to the right of off, but not all the way to start makes some sort of whining/humming sound like it's trying to do something but it can't. Thirdly, the problem can be in the fuel injector pump. Any chance a pto is engaged? Spray DW40 on the rubberboot and work the PTO shift back and forth. Checked battery, fuses, fuel and all are good. I got the tractor to start and it ran fine. You must log in or register to reply here. It drives power from the tractor to the PTO-driven machine. L3450DT-GST, Woods FEL, B7100 HSD, FEL, 60" SB, 743 Bobcat with V2203, and more. Use an air compressor to flush out if anything is clogged. If the problem does not solve yet, replace the fuel filter. As it is a motor device, having problems from time to time is not uncommon. 62. There can be a malfunctioning steering hydraulic cylinder that can cause the problem. You must log in or register to reply here. Manage Settings 1. Do it for at least fine munities. Here are some of them you can face with the solution with it. Check the gear compartment if something like stone or dried mud had stuck there. It is a multipurpose tractor that you can use in various ways. My Kubota l3400 tractor won't start. If not try the second one. I replaced the switch watch that video here: https://www.youtube.com/watch?v=TT0QN_xReOM The switch I got was for a 2013 L3800 Kubota TD-060-53902 yours may have a different number I did see some online but I would check your local Kubota dealer first. Was asked to take a look at this problem and was solved by installing Starter Relay Kit That he bought from john deer but will work on any tractor I would think. Kubota is one of the most reliable agricultural vehicles to choose from. You are using an out of date browser. L3400DT W/ LA463 FEL and L235DT W/ BF400 Loader. Luckily, all these parts are much less money than just one hour of labor. I am thinking the fuel solenoid is bad or could it be the relay not supplying enough power to solenoid to get it to work? They wanted 110ish for the shop manual for my L2501. else. he kinda thinks the fuel pump went out, any way to test that, anything else i should do next, don't really know to much about tractors, but the only tractor place we have around here wants $900 to tow it, and $250 a hour to work on it. Continue with Recommended Cookies. I tried the solution proposed by crbr, rocking the transmission pedal - and it worked - made my day! It will have issues over time as it is made for heavy-duty work. what does the volt meter say when you try to start it. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. You must log in or register to reply here. The dash lights stay strong and do not dim when the key is turned. .Sometimes it starts, then dies. Kubota Tractor Don't Start? Try cleaning your battery post and ground cable. Why is my diesel engine stalling in Kubota L3400? To view the purposes they believe they have legitimate interest for, or to object to this data processing use the vendor list link below. Kubota L3400 starter won't engage. Anyone have any ideas on what to do next? Standard Transmission. Though it is a renowned brand, unfortunately, there are some problems you may face. Firstly, check the fuel line. I did try the fuel solenoid after I removed it and the rod does not move when starting the tractor. If voltages are all good when attempting a start, but starter will not engage, then battery voltage is not getting to the starter or the return path is high resistance/open. Air in the fuel line. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. It generally happens when algae grow inside the fuel bowl. Fuel flow issues are the most common reason for Kubota L3400 to stop working after running for a while. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. I followed the ignition procedure, indicator lights are fine, but when I turn the key I just get one beep followed by nothing, no clicks, nothing. The other switches to look for are on the clutch pedal, on the range shifter if it is a standard shift or one just above the center of the floor board if it is a hydrostat. Unfortunately, not all tractor is perfect. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. I am thinking maybe the ignition switch? To test circuits, fuses and switches use a multimeter tester you can get one here: http://amzn.to/2A5ihXN , you check continuity of circuitssimple example: if you have a standard fuse you put the test wires on either end if fuse is blown it wont show on your meter, if its good needle will go up showing that current can flow through it(Continuity) if your multi-meter doesn't have a dedicated continuity test mode, you can still perform a continuity test. Try rocking the hydrostatic pedal back and forth, allowing it to return to it's functional position on it's own. Thats where I would start, back on the battery. I disconnected the two wires and plugged them into themselves and it started right away now it doesn't turn over at all. Press J to jump to the feed. If its still on, check for the cable which runs from the PTO shift and goes into the transmission case under the seat. Kubota L3400 2006 will turn over but not start. Once i had it running with the fuel solenoid out I had to get the tractor to turn off so I engaged it into gear and stood on the brake which shit the tractor off. Kubota L3400 tractor overview. This sub Reddit is meant for everything and all things tractor and tractor related things. Thanks for the Kubota books site. What does hang up is the PTO safety hookup on the PTO lever itself ( right side of wheel). Removed the solenoid and the tractor started, had to restrict airflow since the fuel solenoid was not connected.. Hey guys. My relatively new (71 hours) Kubota L3400 will not start. The dash lights come on, but when I turn the key all the way there is no click or response at all from the starter. There are 2 coils in there and when the switch is the start position, it puts power to the "pull in coil", when the switch drops into the run position it moves the current to the "hold in coil". Create an account to follow your favorite communities and start taking part in conversations. Always consult equipment operator's manual and follow safety instructions before operating or servicing any tractor or equipment, or attempting any task. I thought with a dead battery I would hear clicking, when turning the key. Secondly, check and inspect the fuel filter. Kubota L3400DT-IF 4 WD Tractor, Serial . Read somewhere that the fuel solenoid can cause the issue. called kubota and other parts places, they have no idea what it is, can't find a pic of it anywhere, so we just put a switch on it for now. It is hard to believe that two little wires control the whole contraption. OrangeTractorTalks brings together Kubota enthusiasts from around the world, into one place, purpose built just for them. Maybe you just typed it wrong - pto needs to be. This way you will get to know if the battery is dead. TONY, DID YOU CHECK THE PTO LEVER, CLUTCH PEDDLE SWITCH AND HIS THE BATTERY CHARGED UP GOOD NO LOOSE CONECTIONS AND SAFETY SWITCH UNDER SEAT. If it is, you need to replace it. You must log in or register to reply here. Not being able to use any particular gear is not a common problem, but it occurs sometimes. Checking Engine Start System. Yes, if the air was formed in the hydraulic system, it can be stopped completely. Getting fuel and hot battery. Battery fully charged, clicks when key is turned, but not engaging or spinning. My L2800 has done this since newjust not as much now, It has gotten better with age. Put the solenoid back on and it would start but then die immediately. What this does is, it pulls the fuel and takes it to the engine from the fuel tank. 61. But today when I turned the key to start, no click, only the sound of the starter turning. it should do the work. RUBYRUSS only posted a day ago that there was a problem with his L3200. Anyone have any ideas on what to do next? It was fine then. It may not display this or other websites correctly. Might even be your key switch which controls the solenoid. As we also learn about what makes them so reliable, and how to properly start and take care of your small. My tractor is suffering this now, but I do know where to look to get it back running. Fuel tank is half full. This happens infrequently enough for me to forget each time, and I just sit there with a puzzeled look on my face for about 30 seconds. Kubota is a brand of tractor that is very much reliable for many kinds of agricultural work. Two weeks ago is the last time I used my L3400. Checked battery, fuses, fuel and all are good. You must log in or register to reply here. If it is the starter solenoid circuit that is preventing the starter, you can activate the starter at the starter, by bypassing the interlocking safety switches and activating it directly at the starter. Fuel flow issues are the most common reason for Kubota L3400 to stop working after running for a while. Make sure there's flow through the fuel system, start at the filter, then the lift pump, then injection pump, then injectors. Cleaning Air Cleaner Element [Single Element Type] 63. Please explain what you mean by 'won't start': will the starter turn at all or is it all completely dead? The fuel solenoid shuts off fuel or engages linkage that controls fuel distribution. The Shuttle Shift lever is stuck in the middle- it will not go into H/L/Reverse. Create an account to follow your favorite communities and start taking part in conversations. I am going to talk about it elaborately in this article. An example of data being processed may be a unique identifier stored in a cookie. I can't get back to it right now, but I'll have a chance to take another look at it Sunday afternoon and I'll try all your suggestions. shut down tractor in field, You can also do a Biocide treatment and set it for overnight. Here are some of them you can face with the solution with it. Open it, start it and let it run for a few minutes then close it. Do it again if you feel needed. To fix this problem, you need to lean the fuel bowl first. The ignition lights and dash lights turn on with the key on but the engine does not turn over. If it is standard or Shuttle shift , there is a small micro-switch for the neutral of the Shuttle Shifter that does not make contact sometimes , I had to tweak mine slightly (micro-switch contact) once to get it to work correctly . The hold in coil is usually tied into low oil pressure, high temperature, sensors to shut the engine down if there is a problem develop when it's already running So, if there is any link of blockage in it, it can also create a problem. 2023 TractorByNet.com | TractorByNet is a registered trademark of IMC Digital Universe, Inc. Other trademarks on this page are the property of their respective owners. You must log in or register to reply here. kubota L3500 cranks but won't start (EDIT) not 3500, L3400, and i think he said it was a 2008 model. Separating Rear Axle Case from Brake Case, Manual Transmission and Glide Shift Transmission, Double Acting Type 2 (Floating with Detent), Electronic Instrument Panel (Intellipanel), Testing, Setting and Adjusting by Electronic Instrument Panel (Intellipanel), Checking GST Electric Control System (GST Model Only), Air Conditioner Relay, Blower Relays and Compressor Relay, R134A Refrigerant Recovery and Recycling Machine, Air Conditioner System and Front Windshield Wiper10-S31, Disassembling Differential Gear Assembly (L2800), Disassembling Differential Gear Assembly (L3400), Checking High Pressure Relief Valve Pressure, Separating MID Case from Transmission Case, Hydraulic Pump Test Using Flow-Meter (Power Steering), Hydraulic Pump Test Using Flow-Meter (Three Point Hydraulic System), Relief Valve (for Three Point Hydraulic System), Hydraulic Pump (Three Point Hydraulic System), Kubota L3400 Operator's Manual (94 pages), Care of Danger, Warning and Caution Labels, Instrument Panel, Switches and Hand Controls, Foot and Hand Controls (Manual Transmission Type), Warm-Up Transmission Oil in the Low Temperature Range, Do Not Operate the Tractor at Full Speed for the First 50 Hours, hangssig Lubricating Oil for New Tractors, Travel Adjustment/Suspension Adjustment Knob, Head Light/Turn Signal/Hazard Light Switch, Main Gear Shift Lever & Range Gear Shift Lever [Manual Transmission Type], Range Gear Shift Lever (L-M-H) [HST Type], Unlock the Parking Brake and Slowly Release the Clutch, Depress the Speed Control Pedal [HST Type], Make Preparations for Attaching Implement, Hydraulic Control Unit Use Reference Chart, Liquid Weight Per Tire (75 Percent Filled), Cleaning Grill, Radiator Screen and Oil Cooler, Checking Gauges, Meter and Easy Checker (TM), Cleaning Air Cleaner Element [Single Element Type], Replacing Hydraulic Oil Filter/Replacing Transmission Oil Filter [HST Type], Checking HST Oil Line [HST Type]/Checking Power Steering Line, Every 800/1500/3000 Hours and Every 1/2 Year, Flush Cooling System and Changing Coolant, Handling Precautions for Electrical Parts and Wiring. if your Kubota tractor won't start watch this video - and try this first.
Surveymonkey Choice Eliminator,
Beautiful Funeral Homilies,
Grand Lodge Of Alabama Website,
Articles K